DESCRIPTION
OXYCONTROL is a liquid catalyst compound which
reacts instantly with dissolved Oxygen in water thus
protecting the boiler from Oxygen corrosion. The highly
efficient results achieved, are based on its reaction
time and its ability to bind, to absorb and to counteract
the dissolved Oxygen, even at low temperatures.
Additionally, OXYCONTROL is applicable to all steam
generating and water systems, when the neutralizing
of dissolved carbon dioxide is required.
ADVANTAGES AND CHARACTERISTICS
6 Protects against Oxygen corrosion and can be used
at low temperatures.
6 Very efficient and rapid Oxygen scavenger.
6 Can be used in combination with a number of other
treatment products.
6 Safe to use on any steam generators and steam
boilers experiencing dissolved Oxygen saturation.
6 Cost effective, easy to handle and apply.
PHYSICAL PROPERTIES
OXYCONTROL is a concentrated liquid sulfite compound
with a specialized catalyst for Oxygen binding.
Appearance/Color : Clear, colorless liquid
Odor : Odorless
Specific gravity : 1.08–1.10 gr/cm3 at 20°C
pH value : 9.0–10.0
PACKAGING
Order Number : 673008 (30 ltrs)
Container : Plastic jerrican
APPLICATION AND USE
A. Dosing Procedure
Initially, a volume of 1.2litres per ton of the boiler’s water
must be used for a period of 48 hours. Thereafter, a
dose of 300ml per ton of make-up water is sufficient to
use on a daily basis. However, daily test results should
be taken into account prior to regulating treatment.
B. Sampling and Testing
To achieve optimal results, it is important to adjust the
treated water and maintain boiler conditions by test-
ing water samples on a daily basis or at the very least,
every three days with the MARICHEM WT SULFI TEST
KIT, depending on the adjustment period to maintain
stable sulfite concentrations in the boiler’s water.
The water samples must always be taken from the
same location, as provided from the boiler manufac-
turer. Sound practice suggests sample to be cooled
via a sample cooler. Thereafter, the results may be
evaluated according to the OXYCONTROL TESTING
CHART found below.
C. Feeding Procedure
OXYCONTROL must be fed into the boiler’s feed pump
suction line or into the hot well tank, continuously, by
means of a metering pump. Other conventional ways
may also be used. However, direct feeding to the boiler
is strongly not recommended.
OXYCONTROL TM
OXYCONTROL TESTING CHART
Boiler Pressure OXYCONTROL Range in ppm as Sulfite ions
0–450 PSI 0–20 20–30 30 and over
450–850 PSI 0–10 10–15 15 and over
Results Increase Dosage 25% Satisfactory Daily Rate Decrease Dosage 25%
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
No one rejects, dislikes.
It has survived not only.
All the Lorem Ipsum on.
Many desktop page now.
Will be used in accordance with our Privacy Policy
Reviews
There are no reviews yet.